Title of article :
The effect of a meteorological tower on its top-mounted anemometer
Author/Authors :
Dimitri Perrin، نويسنده , , Niall McMahon، نويسنده , , Martin Crane، نويسنده , , Heather J. Ruskin، نويسنده , , Lawrence Crane، نويسنده , , Brian Hurley، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
The wind-speed at a site can be measured by installing anemometers on top of meteorological (met) towers. In addition to other sources of error, accelerated airflow, or speed-up, around the top of met towers can cause incorrect anemometer measurements. We consider a particular example where an anemometer was located only 2 tower diameters above the met tower. Using a standard computational fluid-dynamics package, we found the maximum error for this configuration to be 2% of the wind-speed. We conclude that a top-mounted anemometer should be located at the windward side of its met tower, raised 5 diameters above the top. This will reduce speed-up error to less than 1%.
Keywords :
Meteorological tower , Anemometer , measurement error , Flow distortion
Journal title :
Applied Energy
Journal title :