Title of article
Optimization of a dual cycle cogeneration system based on a new exergetic performance criterion
Author/Authors
Yasin Ust، نويسنده , , Bahri Sahin، نويسنده , , Ali Kodal، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
13
From page
1079
To page
1091
Abstract
An ecological performance analysis for an irreversible dual-cycle cogeneration system has been
performed. The objective function is called as the exergetic-performance coefficient (EPC) and
defined as the ratio of total exergy output to the loss rate of availability. The general and optimal
performances of the irreversible dual-cycle cogeneration system, having a finite-rate of heat transfer,
heat leak and internal irreversibilities based on the EPC objective function have been investigated.
Comparisons with respect to the optimal total-exergy output are also provided in order to establish
the utility of the new exergetic-performance coefficient. The analyzed results of the dual-cycle cogeneration
system considered, working at maximum EPC conditions, have a significant advantage in
terms of entropy-generation rate and can be used for the selection of optimal design parameters