• Title of article

    Mathematical modeling of multiple-effect evaporators and energy economy

  • Author/Authors

    Durmus Kaya، نويسنده , , H. Ibrahim Sarac، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    7
  • From page
    1536
  • To page
    1542
  • Abstract
    In this study, a mathematical model was developed for multiple-effect evaporators. These evaporators have cocurrent, countercurrent and parallel flow operation options. Each operation was investigated with and without pre-heaters. The effect of pre-heating on evaporation process was investigated from the point of energy economy. A sugar factory’s data was used with the applied models as a case study. The results obtained for pre-heated and non-pre-heated situations were compared with each other. The maximum COP is found as 3.33 for countercurrent operation with pre-heating. The minimum COP is 2.57 for parallel flow operation without pre-heating.
  • Keywords
    Energy economy , Mathematics model , modeling , Multiple-effect evaporators
  • Journal title
    Energy
  • Serial Year
    2007
  • Journal title
    Energy
  • Record number