Title of article
Mathematical modeling of multiple-effect evaporators and energy economy
Author/Authors
Durmus Kaya، نويسنده , , H. Ibrahim Sarac، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
1536
To page
1542
Abstract
In this study, a mathematical model was developed for multiple-effect evaporators. These evaporators have cocurrent, countercurrent
and parallel flow operation options. Each operation was investigated with and without pre-heaters. The effect of pre-heating on
evaporation process was investigated from the point of energy economy. A sugar factory’s data was used with the applied models as a
case study. The results obtained for pre-heated and non-pre-heated situations were compared with each other. The maximum COP is
found as 3.33 for countercurrent operation with pre-heating. The minimum COP is 2.57 for parallel flow operation without pre-heating.
Keywords
Energy economy , Mathematics model , modeling , Multiple-effect evaporators