Title of article
Mass transfer conditions on a perforated electrode support vibrating in an electrolytic cell
Author/Authors
P. Venkateswarlu، نويسنده , , N. Jaya Raj ، نويسنده , , D. Subba Rao ، نويسنده , , T. Subbaiah، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
8
From page
349
To page
356
Abstract
The limiting current data are measured at copper microelectrodes fixed flush with the surface of an electrode support—a square
perspex plate. The data are obtained by vibrating the electrode support in an electrolytic cell using electrochemical method. The
variables covered in this study are amplitude, frequency and diameter of the perforation on the electrode support. The electrolyte
is 0.01 N potassium ferricyanide, 0.01 N potassium ferrocyanide and 0.5 N sodium hydroxide. It is found that the limiting current
increased with increased frequency and amplitude. The limiting current decreased with increase in the diameter of the perforation
Keywords
Amplitude , perforation , Electrolytic