Abstract :
Vertically perforated bricks were developed with the view to building environmentally friendly houses since they make insulating materials
unnecessary. Indeed, walls can be constructed without any other materials than clay and mortar. Furthermore, they offer better mechanical
properties than horizontally perforated ones. However, heat transfer in this geometry, and particularly the influence of the assembly method, is
not totally known. In this numerical study, we propose to verify that convection heat transfer is negligible in the perforations. This condition is
necessary to increase the thermal resistance of the brick.We then show that a masonry bedded on several strips does not penalize the thermal
performance of the wall. A particular study of the ruptures concludes that the convection present in these regions is a local phenomenon
preferable to the thermal bridges caused by continuous mortar joints.
Keywords :
Vertically perforated brick , Numerical study , convection