• Title of article

    Effects of combined heat and mass transfer on heating load in building drying period

  • Author/Authors

    Fanhong Kong، نويسنده , , Maoyu Zheng، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    9
  • From page
    1614
  • To page
    1622
  • Abstract
    In initial used building with EPS walls, the wall still contains a considerable amount of water that evaporates over time. In order to analyze the effect of moisture levels on a drying building energy performance, the heat and moisture coupling transfer of building wall with multilayer composition in the cold serious area Harbin, China, was simulated. The freezing of liquid moisture in exterior envelope was considered and the moisture content gradient was used as mass transfer driving forces. The effect of some impact factors, as initial moisture content, vapor retarder, interior wallpaper and exterior glazed brick on the wall energy consumption were also analyzed. It is concluded that the effect of drying are most significant during the first year of building initial use. The drying rate of the new building was significantly high in the first year, especially in the first few months. These changes during initial drying often account for a significant fraction of the overall load and have notable effect on the building energy performance.
  • Keywords
    Energy performance , Cold serious area , Coupling transfer , Liquid moisture freezing , Driving force
  • Journal title
    Energy and Buildings
  • Serial Year
    2008
  • Journal title
    Energy and Buildings
  • Record number

    420162