Title of article :
Calibration and measurement procedures implemented to work with a seven-hole directional pressure probe in the mapping of pressure and velocity wind tunnel flows are reported in this paper. The performances of two different methods used to derive the flow
Author/Authors :
Yaohua Zhao، نويسنده , , Takaharu Tsuruta، نويسنده , , Chaoyue Ji، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
8
From page :
9
To page :
16
Abstract :
Saturated nucleate boiling heat transfer and critical heat flux (CHF) were experimentally studied in a confined space which consisted of two horizontal surfaces with a lower heated surface and an upper mesh screen. The nucleate boiling heat transfer was much enhanced in such a confined space, because the mesh screen kept primary vapor bubbles forming coalescence bubble within the confined space in lower heat flux region and allowed the vapor bubble to easily escape from the confined space in higher heat flux region. Observation by a high-speed camera showed that the behaviors of vapor mushroom over the mesh screen were not significantly different from that in the unconfined pool boiling at higher heat flux. The peripheral conditions of the confined space had no obvious effects on the heat transfer characteristics. The experimental CHF data showed a good agreement with the theoretical predictions based on the microlayer model proposed by some of the present authors.
Keywords :
Vapor bubble , Saturated nucleate boiling , heat transfer enhancement , Boiling heat transfer , Confined space
Journal title :
Experimental Thermal and Fluid Science
Serial Year :
2003
Journal title :
Experimental Thermal and Fluid Science
Record number :
420387
Link To Document :
بازگشت