Title of article
In tube heat transfer characteristics of R410A and R404A have been experimentally investigated in a smooth horizontal tube made of stainless steel with an inner diameter of 6 mm and a length of 6 m, uniformly heated by the Joule effect. The evaporation pr
Author/Authors
Vitaliy Nezym، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
7
From page
209
To page
215
Abstract
Application of casing treatment in compressor has been found to give substantial improvement in compressor stable operating range. An experimental investigation has been carried out with one variant of casing treatment, an entire annular recess (EAR) over the compressor rotor blades. Various tip clearances and two groups of annular recesses (without and with penetration of rotor blade tips into casing) were used. The results for 20 such configurations are presented in the proposed paper, analyzed with respect to relative tip clearance and recess relative volume influence on compressor stable operating range.
Keywords
Entire annular recess , Compressor , Stable operation range , Casing treatment
Journal title
Experimental Thermal and Fluid Science
Serial Year
2004
Journal title
Experimental Thermal and Fluid Science
Record number
420399