• Title of article

    Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure

  • Author/Authors

    Andrea Cioncolini، نويسنده , , Lorenzo Santini، نويسنده , , Marco E. Ricotti، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    12
  • From page
    1301
  • To page
    1312
  • Abstract
    Experimental pressure drop results on boiling water flow through three helical coils of tube inner diameter of 4.03 mm and 4.98 mm and coil diameter to tube diameter ratio of 26.1, 64.1 and 93.3 are presented. Both subcooled and saturated flow boiling are investigated, covering operating pressures from 120 to 660 kPa, mass fluxes from 290 to 690 kg m−2 s−1 and heat fluxes from 50 to 440 kW m−2. Existing correlations for subcooled flow pressure drop are found not capable to fit the present subcooled database, while the measurements in saturated flow conditions are successfully reproduced by existing correlations for both straight and coiled pipe two-phase flow. The experimental database is included in tabular form.
  • Journal title
    Experimental Thermal and Fluid Science
  • Serial Year
    2007
  • Journal title
    Experimental Thermal and Fluid Science
  • Record number

    420444