Title of article :
Flow pattern and model development for coaxially placed entry region coil-disc assembly as turbulence promoter in circular conduits
Author/Authors :
Vaka Murali Mohan، نويسنده , , P. Rajendra Prasad، نويسنده , , V. Sujatha، نويسنده , , S. Sarveswara Rao، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
6
From page :
1748
To page :
1753
Abstract :
Flow pattern and model development for coaxially placed entry region coil-disc as turbulence promoter in circular conduit have been presented in this paper. The electrolyte was equimolal potassium ferricyanide, potassium ferrocyanide and excess sodium hydroxide. The mass transfer correlation is based on law of the wall similarity. The variables covered in this study are the flow rate of the electrolyte, the geometric parameters of the promoter – pitch of the coil from 0.015 m to 0.035 m, length of the coil 0.01 m to 0.125 m, disc diameter from 0.02 m to 0.04 m, height of the disc from 0 m to 0.50 m, velocity of the fluid from 0.0591 m/s to 0.2751 m/s. The correlation may be extended to a wider range of parameters by virtue of the law of the wall. Experimental mass transfer function in terms of geometric parameters have been developed and presented.
Keywords :
Circular conduit , mass transfer , modeling , Entry region coil , Turbulence promoter , disc
Journal title :
Experimental Thermal and Fluid Science
Serial Year :
2007
Journal title :
Experimental Thermal and Fluid Science
Record number :
420494
Link To Document :
بازگشت