Title of article
Virial Coefficients from Burnett Measurements for the R116 + CO2 System
Author/Authors
G. Di Nicola، نويسنده , , G. Giuliani، نويسنده , , G. Passerini، نويسنده , , F. Polonara and R. Stryjek ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
11
From page
1437
To page
1447
Abstract
PVTx measurements for the R116+CO2 system for four isotherms (283, 304,
325 and 346 K) were performed. In total, 16 runs were performed in a pressure
range from 5100 to 140 kPa. Seven runs along four isotherms in a pressure
range from 3400 to 280 kPa were performed for pure hexafluoroethane
(R116), and the second and third virial coefficients were derived. The values
of the virial coefficients for CO2 were adopted from our previous measurements.
The second and third virial coefficients along with the second and
third cross-virial coefficients were derived from the mixture results. The Burnett
apparatus was calibrated using helium. The experimental uncertainty in
second and third virial coefficients was estimated to be within ±2 cm3· mol−1
and ±500 cm6·mol −2, respectively.
Keywords
Burnett apparatus , CO2 + R116 , experimental PVTx , R116 , virial coefficients , CO2