Title of article :
Uncertainty of Thermal Diffusivity Measurements by Laser Flash Method
Author/Authors :
B. Hay، نويسنده , , J. R. Filtz، نويسنده , , J. Hameury and L. Rongione ، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
The laser-pulse method is a well-established nonsteady-state measurement
technique for measuring the thermal diffusivity, a, of solid homogeneous
isotropic opaque materials. BNM-LNE has developed its own bench based
on the principle of this method in which the thermal diffusivity is identified
according to the “partial time moments method.” Uncertainties of thermal
diffusivity by means of this method have been calculated according to
the ISO/BIPM “Guide to the Expression of Uncertainty in Measurement.”
Results are preseInted for several cases (Armco iron, Pyroceram 9606) in the
temperature range from 20 to 800◦C. The relative expanded (k =2) uncertainty
of the thermal diffusivity determination is estimated to be from ±3 to
±5%, depending on the material and the temperature
Keywords :
thermal diffusivity , laser flash method , Pyroceram , uncertainty , Armco iron
Journal title :
International Journal of Thermophysics
Journal title :
International Journal of Thermophysics