Title of article :
Measurement of the Viscosity of Dilute Magnetic Fluids
Author/Authors :
Qiang Li، نويسنده , , Yimin Xuan and Jian Wang ، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
The capillary tube viscometer is used to measure the viscosity of aqueous
magnetic fluids under the influence of parallel and perpendicular magnetic
fields. The effects of the volume fraction of the suspended magnetic particles,
the concentration of surfactants, and the external magnetic field strength, as
well as the orientation, on the viscosity of the magnetic fluid are analyzed.
The experimental results show that the viscosity of the sample magnetic fluids
increases with increases in the concentrations of suspended magnetic particles
and surfactants. The external magnetic field is also an important factor
that affects the viscosity of the magnetic fluid. The viscosity first increases
with the magnetic field and finally approaches a constant as the magnetization
attains a saturation state. For the same magnetic fluid, the viscosity in
a perpendicular magnetic field is larger than that in a parallel magnetic field
for the same magnetic field
Keywords :
viscosity. , magnetic effect , Magnetic fluid
Journal title :
International Journal of Thermophysics
Journal title :
International Journal of Thermophysics