Title of article
Thermal Diffusivity Measurements in Fluids Containing Metallic Nanoparticles using Transient Thermal Lens
Author/Authors
J. F. S?nchez Ram?rez، نويسنده , , J. L. Jiménez-Pérez، نويسنده , , R. Carbajal Valdez، نويسنده , , A. Cruz Orea، نويسنده , , R. Gutiérrez FueIntes and J. L. Herrera-Pérez ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
8
From page
1181
To page
1188
Abstract
Thermal diffusivity measurements are carried out in nanofluids, solutions
containing gold nanoparticles (∼10–40nm size), using the mode-mismatched
dual-beam thermal lens technique. An Ar+ laser is used as the heating
source, and an iIntensity stabilized He–Ne laser serves as the probe beam.
This technique provides a reliable photothermal alternative for measuring
thermal diffusivities of nanofluids and semitransparent samples. The characteristic
time constant of the transient thermal lens was obtained by fitting the
experimental data to the theoretical expression for the transient thermal lens.
From this characteristic time, the fluid thermal diffusivity, which increases
when the particle sizes increase was obtained. The size of the nanoparticles
was obtained from transmission electron microscopy (TEM) analysis.
Keywords
photothermal phenomena , Nanoparticle , thermal diffusivity , thermallens , nanofluids , TRANSMISSION ELECTRON MICROSCOPY