Title of article
Deposition of Aerosol Particles in Contraction Fittings
Author/Authors
Muyshondt، نويسنده , , Arnold; McFarland، نويسنده , , Andrew R.; Anand، نويسنده , , N. K، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
12
From page
205
To page
216
Abstract
Particle deposition was measured in contraction fittings with halfangles
of 12°, 45°, and 90°. It was found that for a given contraction half angle, the
losses in a contraction fitting correlate well with the parameter Stk(1-Ao/A)
where: Stk is a Pich-type Stokes number based on inlet velocity and outlet
diameter, Ao is the outlet area, and Aj is the inlet area. A correlation developed
from the experimental results allows prediction of the particle losses in contraction
fittings as a function of Stokes number, area ratio, and contraction half-angle. Test
conditions on which the correlation was based include a range of 0.001 < Stk (l-Aol
A) < 100. Area ratios AoIA; used in the tests were 0.062, 0.215, and 0.571, and the
test conditions encompassed Reynolds numbers based on downstream port diameter
of 1120 to 58,500. The aerosol particle deposition in the contraction fitting was also
modeled numerically and the numerical results show good agreement with the
experimental data. Flow turbulence was taken into account in the numerical work
using a standard k-e closure model
Journal title
Aerosol Science and Technology
Serial Year
1996
Journal title
Aerosol Science and Technology
Record number
430299
Link To Document