• Title of article

    Gas Collection Efficiency and Entrance Flow Effect of an Annular Diffusion Denuder

  • Author/Authors

    B.، نويسنده , , J. Fan; Y.، نويسنده , , S. Cheng; H.، نويسنده , , C. Yeh ، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    8
  • From page
    113
  • To page
    120
  • Abstract
    In air sampling, an annular diffusion denuder (ADD) is often used to trap specific gases from an air sample stream. In a dimensional analysis, the gas collection efficiency was shown to be dependent on two parameters: the Peelet number and the annulus radii ratio. Also, the entrance flow effect on the gas collection efficiency was examined. In determining the gas collection efficiency of an ADD, the gas concentration and flow field were solved numerically from their governing equations using a computational fluid dynamics technique. The collection efficiency of gas diffusing to the annulus wall was then calculated from the gas concentration and velocity profiles. After validating the methodology, a parametric calculation of the gas collection efficiency was made, and a mathematical model based on the calculation was developed
  • Journal title
    Aerosol Science and Technology
  • Serial Year
    1996
  • Journal title
    Aerosol Science and Technology
  • Record number

    430320