Title of article :
Gas Collection Efficiency and Entrance Flow Effect of an Annular Diffusion Denuder
Author/Authors :
B.، نويسنده , , J. Fan; Y.، نويسنده , , S. Cheng; H.، نويسنده , , C. Yeh ، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Abstract :
In air sampling, an annular diffusion denuder (ADD) is often used to
trap specific gases from an air sample stream. In a dimensional analysis, the gas
collection efficiency was shown to be dependent on two parameters: the Peelet
number and the annulus radii ratio. Also, the entrance flow effect on the gas
collection efficiency was examined. In determining the gas collection efficiency of an
ADD, the gas concentration and flow field were solved numerically from their
governing equations using a computational fluid dynamics technique. The collection
efficiency of gas diffusing to the annulus wall was then calculated from the gas
concentration and velocity profiles. After validating the methodology, a parametric
calculation of the gas collection efficiency was made, and a mathematical model
based on the calculation was developed
Journal title :
Aerosol Science and Technology
Journal title :
Aerosol Science and Technology