Title of article :
Analysis of operational filtration data part III: re-entrainment and incomplete cleaning of dust cake
Author/Authors :
Smith، نويسنده , , Duane H.; Powell، نويسنده , , Victor; Ahmadi، نويسنده , , Goodarz; Ferer، نويسنده , , Martin ، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Abstract :
Operational data for the hot-gas filtration system of the Integrated
Gasification and Cleanup Facility (IGCF) at the Federal Energy Technology Center
are carefully analyzed. A model that includes re-entrainment of filter-cake fragments
following cleaning of the candle filters, as well as incomplete removal of cake from
the filters by the cleaning backpulses of compressed air, is developed and used to
interpret the data. The parameters of the model are evaluated with a least-square
error fit procedure. It is shown that inclusion of the re-entrainment model significantly
improves the fit to the data during the short interval (;50 s after each
backpulse) during which re-entrainment is predicted to occur by particle-transport
modeling. The re-entrainment/incomplete-cleaning model is used to evaluate the
buildup of filter-cake thickness and the filter-cake permeability. Both effects were
significant for the data analyzed.