Title of article :
Injection related cooling in the Unit 13 area of theSoutheast Geysers, California, usa
Author/Authors :
K. P. Goyal، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Abstract :
Eight years of water injection into southeast Geysers well CA 845A!0 has been bene_cial
and without any water breakthrough to nearby producers[ Production wells with maximum
injection bene_t did not show any wellhead temperature or enthalpy degradation for approxi!
mately _ve years[ Production wells which showed no obvious injection e}ect did not exhibit
any thermodynamic degradation for up to six years[ Producers located to the northwest of CA
845A!0 have not displayed any thermal degradation so far[ The thermal front appears to grow
towards the southwest and east of the injection well[ Upon arrival of the thermal front\ a drop
of 0[2 4[6>F "9[6 2[1>C# per year in wellhead temperature and 9[2 1[2 Btu:lbm "9[6 4[2 kJ:kg#
per year in wellhead enthalpy has been observed[ The arrival of the thermal front signi_es a
slowing down in boiling rate and\ therefore\ the recovery rate of the injected water[ 0888
Published by Elsevier Science Ltd on behalf of CNR[ All rights reserved[
Keywords :
Injection^ Vapor!dominated reservoirs^ The Geysers^ California^ USA
Journal title :
Geothermics
Journal title :