• Title of article

    Monitoring of geothermal steam moisture separator efficiency

  • Author/Authors

    Lee Machemer، نويسنده , , Otakar Jonas، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    11
  • From page
    587
  • To page
    597
  • Abstract
    A new Low Emission Atmospheric Metering Separator (LEAMS) was developed by Two-Phase Engineering and Research, Inc. and tested by Sandia National Laboratories in parallel with a cyclone separator at the Coso, California geothermal field. In order to determine the efficiency of the separator, a Jonas, Inc. Particle Monitor was installed in the exhaust from each separator to measure the mass flow rate and size distribution of water droplets exiting the separators. These tests provided semi-quantitative data on the improved separation provided by the LEAMS, as well as verification of the Jonas, Inc. Particle Monitor on geothermal steam systems. © 2004 CNR. Published by Elsevier Ltd. All rights reserved.
  • Keywords
    Geothermal , Steam , Droplet , Monitor , Cyclone , LEAMS , Particle , Separator
  • Journal title
    Geothermics
  • Serial Year
    2004
  • Journal title
    Geothermics
  • Record number