Title of article :
Interpretation of a well interference test at the Chingshui geothermal field, Taiwan
Author/Authors :
Kai C. Fan، نويسنده , , M.C. Tom Kuo، نويسنده , , Kan F. Liang، نويسنده , , C. Shu Lee، نويسنده , , Shin C. Chiang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
Production in the liquid-dominated Chingshui geothermal field is largely from a fractured zone
in the Jentse Member of the Miocene Lushan Formation. The geological data strongly indicate a
possibility of linear-flow geometry on a field-wide scale. This was confirmed by re-analyzing the
results of a multiple-well interference test performed in 1979. Radial and linear-flow models were
used in this process. An evaluation of computed reservoir transmissivities and well capacities indicated
that a linear model fitted the interference test data significantly better than a radial model. The linearflow
model that was developed for the Chingshui reservoir was also instrumental in obtaining an
improved estimation of the geothermal fluid reserves (i.e., fluid-in-place).
© 2004 CNR. Published by Elsevier Ltd. All rights reserved.
Keywords :
geothermal reservoir , Taiwan , Well tests , Chingshui
Journal title :
Geothermics
Journal title :