• Title of article

    Energy and exergy analysis of the Gonen geothermal district heating system, Turkey

  • Author/Authors

    Leyla Ozgener، نويسنده , , Arif Hepbasli، نويسنده , , Ibrahim Dincer، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    14
  • From page
    632
  • To page
    645
  • Abstract
    This paper describes a performance evaluation of the Gonen geothermal district heating system (GGDHS) in Balikesir, Turkey, based on energy and exergy analyses. The exergy destructions in the overall GGDHS are quantified and illustrated using energy and exergy flow diagrams for a reference temperature of 6 ◦C. The results indicate that the exergy destructions in the system occur primarily as a result of losses in the pumps, heat exchangers, and pipelines, as well as losses associated with cooled geothermal waters injected back into the reservoir. These losses amount to 14.81%, 7.11%, 1.06%, and 12.96% of the total exergy input to the GGDHS, respectively. Both energy and exergy efficiencies of the overall GGDHS were investigated to analyze and improve system performance. The efficiencies were determined to be 45.91% and 64.06%, respectively. © 2005 CNR. Published by Elsevier Ltd. All rights reserved
  • Keywords
    Energy analysis , Geothermal energy , Geothermal district heating , Exergy analysis
  • Journal title
    Geothermics
  • Serial Year
    2005
  • Journal title
    Geothermics
  • Record number