Title of article :
Rapid partial charging of lead/acid batteries
Author/Authors :
T.G. Chang، نويسنده , , D.M. Jochim، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
8
From page :
103
To page :
110
Abstract :
Rapid partial-charge cycling tests, in which the battery received only 5 or 15 min of high-current charge in each cycle, were carried out for a number of commercial lead/acid batteries. It was found that valve-regulated batteries retained their capacity well, and their full discharge capacity was usually recovered in an extended recharge following five to ten rapid partial-charge cycles. Flooded batteries, tested under stationary conditions, did not perform as well as the valve-regulated batteries, which may have been caused by electrolyte stratification. The experimental data indicated that rapid charging was beneficial to the cycle life of a battery. Heat analysis indicated that the ohmic heat was the major contributor to the total heat generated in the rapid partial-charging process.
Keywords :
Lead/acid batteries , Charge , electrolytes , Heating
Journal title :
Journal of Power Sources
Serial Year :
1997
Journal title :
Journal of Power Sources
Record number :
438780