Title of article :
Summary of electrical test results for valve-regulated lead-acid (VRLA) batteries
Author/Authors :
J. Crow، نويسنده , , I. Francis Cheng، نويسنده , , Maria P. Butler، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
7
From page :
241
To page :
247
Abstract :
Under the auspices of the US Department of Energy, Energy Storage Systems (ESS) Program at Sandia National Laboratories, electrical tests were performed on two valve-regulated lead-acid (VRLA) batteries to compare the effects of several design improvements, evaluate their applicability to stationary applications, and determine their service lives. One battery represented a baseline design, and the other an improved design resulting from a development project. The two nine-cell, 1050–1200 A h, C8/8 batteries were tested over a 7-year period using primarily a 100% depth of discharge and approximately a C8/8 discharge regime. A variety of charge profiles were investigated and characterized. Both batteries reached end-of-life after several hundred cycles. This paper will describe these results and overall life data, and comparison information will be summarized.
Keywords :
Battery testing , battery charging , Battery life and performance , Valve-regulated lead-acid batteries
Journal title :
Journal of Power Sources
Serial Year :
2001
Journal title :