Title of article :
Diagnostic tool to detect liquid water removal in the cathode channels of proton exchange membrane fuel cells
Author/Authors :
H.P. Ma، نويسنده , , H.M. Zhang، نويسنده , , J. Hu، نويسنده , , Y.H. Cai، نويسنده , , B.L. Yi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
5
From page :
469
To page :
473
Abstract :
A transparent PEMFC with a single straight channel was designed to study liquid water transport in the cathode channel. The pressure-drop between the inlet and outlet of the channel was measured and used as a diagnostic signal to monitor liquid water accumulation and removal. This method was non-destructive for the fuel cell, and is capable of monitoring the water droplet buildup and removal in the channel on-line directly, and giving real-time liquid water buildup information. The proper velocity for liquid water removal can be determined according to the pressure-drop curve, which was very helpful to design a flow field and to optimize fuel cell operation. Under the study conditions, and to ensure liquid water discharge, the gas velocity should not lower than 2, 3 and 5 m s−1 for 600, 1000 and 1200 mA cm−2, respectively. The results were further verified by visualization in a transparent PEMFC.
Keywords :
flooding , Liquid water removal , Transparent PEMFC , Pressure-drop
Journal title :
Journal of Power Sources
Serial Year :
2006
Journal title :
Journal of Power Sources
Record number :
440761
Link To Document :
بازگشت