• Title of article

    Description of gasket failure in a 7 cell PEMFC stack

  • Author/Authors

    Attila Husar، نويسنده , , Maria Serra، نويسنده , , Cristian Kunusch، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    7
  • From page
    85
  • To page
    91
  • Abstract
    This article presents the data and the description of a fuel cell stack that failed due to gasket degradation. The fuel cell under study is a 7 cell stack. The unexpected change in several variables such as temperature, pressure and voltage indicated the possible failure of the stack. The stack was monitored over a 6 h period in which data was collected and consequently analyzed to conclude that the fuel cell stack failed due to a crossover leak on the anode inlet port located on the cathode side gasket of cell #2. This stack failure analysis revealed a series of indicators that could be used by a super visional controller in order to initiate a shutdown procedure.
  • Keywords
    Stack failure , indicators , Polymer electrolyte membrane fuel cells , GASKET
  • Journal title
    Journal of Power Sources
  • Serial Year
    2007
  • Journal title
    Journal of Power Sources
  • Record number