• Title of article

    Combined measurement of PEMFC performance decay and water droplet distribution under low humidity and high CO

  • Author/Authors

    Toshiaki Murahashi، نويسنده , , Hiroyuki Kobayashi، نويسنده , , Enju Nishiyama، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    8
  • From page
    98
  • To page
    105
  • Abstract
    Measurements of the performance decay for a proton exchange membrane fuel cell (PEMFC) and the observation of water droplets were simultaneously carried out for 4000 h under degradation conditions of low humidity and high CO concentration. An optical cell was designed for observation of water droplets and measurement of the transition points. It was found that as the performance decayed with time, the transition point to a two-phase flow moved toward the cathode exit for conditions of both low humidity and high CO concentration. Performance data showed that under these conditions, there was no pinhole in the membrane or significant mass transport loss observed. It was supposed that the deactivation of electrodes occurred at the cathode inlet and the anode outlet under low humidity and high CO concentration, and that this caused the decay in performance and observed change of the transition point at the cathode. The change of the transition point was computed using a two-dimensional cell model. Performance decay, such as oxygen gain and the cell over-potential, was simulated by changing the value of the exchange current densities of the cathode and anode. Comparison with the experimental results shows good agreement for the total duration of cell operation.
  • Keywords
    degradation , visualization , Water droplet , PEMFC , CO poisoning
  • Journal title
    Journal of Power Sources
  • Serial Year
    2008
  • Journal title
    Journal of Power Sources
  • Record number

    442274