• Title of article

    A pumped heat pipe cold plate for high-flux applications

  • Author/Authors

    J. H. Ambrose، نويسنده , , A. R. Feild، نويسنده , , H. R. Holmes، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1995
  • Pages
    7
  • From page
    156
  • To page
    162
  • Abstract
    The design, development, and testing of a pumped heat pipe cold plate is described, with emphasis on measured performance. The device is designed to integrate high-flux, detachable spacecraft payloads to a pumped thermal control loop. The component evaporates ammonia working fluid to remove waste heat from a payload. The control of the evaporation and phase separation is accomplished using the self-regulating capillary fluid management (SRCFM) concept of Holmes et al. This concept also makes the device performance insensitive to gravity.
  • Journal title
    Experimental Thermal and Fluid Science
  • Serial Year
    1995
  • Journal title
    Experimental Thermal and Fluid Science
  • Record number

    448325