Title of article
The use of an implantable force transducer to measure patellar tendon forces in goats
Author/Authors
Donna L. Korvick، نويسنده , , John F. Cummings، نويسنده , , Edward S. Grood، نويسنده , , John P. Holden، نويسنده , , Seth M. Feder، نويسنده , , David L. Butler، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1996
Pages
5
From page
557
To page
561
Abstract
Patellar tendon (PT) force was measured during activity with an implantable force transducer (IFT) in adult goats. PT force, vertical ground reaction force (VGRF) and the animalʹs speed were recorded for standing, walking and trotting. Following data collection, animals were euthanized and the IFT calibrated in vitro. Standing PT force averaged 207 N. Maximum PT force was approximately 800 N for walking and 1000 N for trotting and occurred at mid-stance. PT force dropped from 200 N at toe-off to 0 N by mid-swing. For each activity, the PT force increased with increases in VGRF. Maximum in vivo PT stress occurred during trotting and measured 29 MPa. This study demonstrates the IFTʹs usefulness in measuring tendon force directly.
Keywords
Tendon , Goats/animal , biomechanics , Force measurements , Patella tendon. , Transducers