Title of article :
Microhardness anisotropy of lamellar bone
Author/Authors :
P. E. Riches، نويسنده , , N. M. Everitt، نويسنده , , A. R. Heggie، نويسنده , , D. S. McNally، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Abstract :
The Knoop microhardness test has been utilised to observe in-plane microhardness anisotropy of rat tibiae. The elongated rhombohedral geometry of the Knoop indenter enables the Knoop microhardness (HK) to be calculated for a given indenter orientation. Two indenter orientations were used the major axis of the indenter was aligned along the length of, and across the mid-sagittal section. The statistical analysis demonstrated that the variation in HK was primarily due to the orientation of the Knoop indenter (p< 0.001). HK was consistently greater when the indenter was aligned with the major diagonal radial on the mid-sagittal section.
Keywords :
Knoop indenter , Anisotropy , Lamellar bone , Material properties. , Collagen fibre orientation
Journal title :
Journal of Biomechanics
Journal title :
Journal of Biomechanics