Title of article :
A telemetry-based device to determine the force–displacement behaviour of materials in high impact loading situations
Author/Authors :
E. K. J. Chadwick، نويسنده , , A. C. Nicol، نويسنده , , Anthony S. Floyd، نويسنده , , T. G. F. Gray، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
5
From page :
361
To page :
365
Abstract :
Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force–displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of electrical foil strain gauges applied to a cylindrical load cell. A piezo-resistive accelerometer (±500 g) is used to calculate the displacement of the device through double integration of its signal, with the impact velocity used as a boundary condition. The signals from the strain gauge circuit and the accelerometer are sampled at 2500 Hz. The data are transmitted to a receiver via telemetry using a 418 MHz FM transmitter and from the receiver to a laptop PC via the serial port. Calibration of the device is described and sample results showing forces up to 2500 N and displacements up to 0.04 m are presented.
Keywords :
Stab , biomechanics , telemetry , Knife , strain gauge
Journal title :
Journal of Biomechanics
Serial Year :
2000
Journal title :
Journal of Biomechanics
Record number :
450997
Link To Document :
بازگشت