Title of article
Influence of ligament stiffness on the mechanical behavior of a functional spinal unit
Author/Authors
Thomas Zander، نويسنده , , Antonius Rohlmann، نويسنده , , Georg Bergmann، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
5
From page
1107
To page
1111
Abstract
Data on the stiffnesses of spinal ligaments are required for analytical studies on the mechanical behavior of spinal segments. Values obtained experimentally vary widely in the literature. A finite element model of an L3/L4 functional spinal unit was used to determine the influence of ligament stiffness on intersegmental rotation and forces in the ligaments. The lowest values for ligament stiffness selected from the literature were used in one set of calculations, and the highest values were simulated in a second set. The nonlinear model was loaded with pure moments of 7.5 and 15 Nm in the three main anatomical planes. The mechanical behavior of the functional spinal unit was strongly influenced by ligament stiffness. In some cases, a ligament with low stiffness does not carry any load, while the same ligament with high stiffness has to carry a high load. This indicates that finite element models of spinal segments have to be validated and that a realistic quantitative prediction of ligament forces is extremely difficult
Keywords
lumbar spine , Spinal ligaments , Finite element method , Stiffness
Journal title
Journal of Biomechanics
Serial Year
2004
Journal title
Journal of Biomechanics
Record number
451801
Link To Document