Title of article :
A reproducible method for studying three-dimensional knee kinematics
Author/Authors :
Nicola Hagemeister، نويسنده , , Gerald Parent، نويسنده , , Maxime Van de Putte، نويسنده , , Nancy St-Onge، نويسنده , , Nicolas Duval، نويسنده , , Jacques de Guise، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
6
From page :
1926
To page :
1931
Abstract :
The methods used in movement analysis often rely on the definition of joint coordinate systems permitting three-dimensional (3D) kinematics. The first aim of this research project was to present a functional and postural method (FP method) to define a bone-embedded anatomical frame (BAF) on the femur and tibia, and, subsequently, a knee joint coordinate system. The repeatability of the proposed method was also assessed. Using FP method to define the BAFs, 4 kinematic parameters (flexion/extension, abduction/adduction, tibial internal/external rotation, and antero-posterior translation) were computed for 15 subjects walking on a treadmill. The repeatability for all four kinematic parameters was then assessed, using intra- and inter-observer settings. After pooling the results for all observers, the mean repeatability value ranged between 0.4° and 0.8° for rotation angles and between 0.8 and 2.2 mm for translation.
Keywords :
Anatomical frames , validation , Knee kinematics , Functional method , Three-dimensional kinematics
Journal title :