Title of article :
The temporal response of the friction coefficient of articular cartilage depends on the contact area
Author/Authors :
Michael J. Carter، نويسنده , , Ines M. Basalo، نويسنده , , Gerard A. Ateshian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
4
From page :
3257
To page :
3260
Abstract :
The hypothesis of this study is that the time constant for the transient increase in friction coefficient of articular cartilage under a constant load is proportional to the size of the contact area, as predicated by the dependence of the frictional response on interstitial fluid pressurization. This hypothesis is verified experimentally from measurements of the frictional response of bovine articular cartilage disks of three different diameters (4, 6 and 8 mm) against glass. At two different applied stresses (0.127 and 0.254 MPa), the coefficient of determination of a linear regression of the time constant versus the contact area yielded R2=0.892 and R2=0.979 (p<0.001). The results of this study provide a cogent explanation for the expectation that the friction coefficient in situ will not achieve the elevated equilibrium values observed under common testing conditions.
Keywords :
Cartilage , contact area , Interstitial fluid pressurization , Friction
Journal title :
Journal of Biomechanics
Serial Year :
2007
Journal title :
Journal of Biomechanics
Record number :
452789
Link To Document :
بازگشت