Title of article :
Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography: Comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography Ori
Author/Authors :
Marcel Peltier، نويسنده , , David Vancraeynest، نويسنده , , Agnès Pasquet، نويسنده , , Taniyel Ay، نويسنده , , Véronique Roelants، نويسنده , , Anne-Marie Dʹhondt، نويسنده , , Jacques A. Melin، نويسنده , , Jean-Louis J. Vanoverschelde، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
8
From page :
257
To page :
264
Abstract :
Objectives The purposes of this study were to test whether quantitative real-time myocardial contrast echocardiography (RT-MCE) can detect coronary disease during pharmacologic stress and to compare this approach with single-photon emission computed tomography (SPECT). Background Assessing myocardial perfusion during stress is important for the diagnosis and risk stratification of patients with coronary disease. Methods Thirty-five patients referred for coronary angiography underwent RT-MCE and technetium-99m methoxyisobutylisonitrile (MIBI) SPECT at baseline and after 0.84 mg/kg dipyridamole. The modalities of RT-MCE and SPECT were analyzed both qualitatively and quantitatively. For this purpose, myocardial flow reserve was calculated from microbubble replenishment curves, and regional MIBI uptake was measured on circumferential profiles. Segments and vascular territories were categorized into five groups with increasing stenosis severity by quantitative coronary angiography. Results With dipyridamole, beta and A × beta increased in all but the highest stenosis severity group. The increase in beta and A × beta was significantly lower in territories supplied by stenotic arteries than in those supplied by arteries with <50% stenosis. Graded decreases in beta and A × beta reserves were noted with increasing stenosis severity. Using the cutoff value of 2.00 for beta reserve, quantitative RT-MCE correctly identified 97% of the territories supplied by significant stenoses and 82% of those supplied by normal arteries. In contrast, quantitative SPECT correctly identified only 71% of the territories supplied by significant stenoses and 81% of those supplied by normal arteries. Conclusions This study shows that RT-MCE, with dipyridamole, can define the presence and severity of coronary disease in a manner that compares favorably with quantitative SPECT.
Keywords :
CAD , SPECT , technetium-99m , coronary artery disease , Left ventricular , 99mTc , ROC , Single-photon emission computed tomography , MI , LV , MBF , myocardial blood flow , mechanical index , MIBI , methoxyisobutylisonitrile , QCA , quantitative coronary angiography , receiver-operating characteristics , RT-MCE , real-time myocardial contrast echocardiography
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2004
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
458841
Link To Document :
بازگشت