Title of article :
A cardiologist in the carotids Review Article
Author/Authors :
William A Gray، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
4
From page :
1602
To page :
1605
Abstract :
Carotid endarterectomy for stroke prevention has been the standard of care for 50 years in patients with extra-cranial carotid bifurcation disease. Over the past decade, carotid stenting has emerged as a viable alternative to surgery. Combined with filter embolic protection devices, both a randomized control trial (Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy registry [SAPPHIRE]) as well as registry data (ACCULINK for Revascularization of Carotids in High Risk Patients registry [ARCHeR] and Registry Study to evaluate the Neuroshield Bare-Wire Cerebral Protection System and X-Act Stent in patients at high risk for Carotid Endarterectomy [SECuRITY]) have compared favorably to endarterectomy in patients at high risk for operative revascularization. Conditions associated with high operative risk included patients with significant cardiac, pulmonary, and renal disease; previous neck operation; previous radiation; and anatomically difficult surgical access. On the basis of these results, a carotid stent system approved by the Food and Drug Administration (FDA) is anticipated in 2004. Although this will be a welcome addition to endarterectomy in the armamentarium of therapeutic options for patients with carotid disease, several challenges lie ahead. Coverage and reimbursement for the carotid stenting has been severely restricted to include only those procedures performed as part of an FDA investigational device exemption trial protocol, and a national noncoverage decision will have to be reckoned with before broader coverage can be put into place (assuming FDA approval). In addition, the level of national expertise in carotid endovascular intervention is limited, and training will need to be tailored to the three specialties likely to perform the procedure: cardiology, radiology, and vascular surgery. Each of these specialties will have specific, and different, requirements for their training, further complicating the task of education.
Keywords :
Security , archer , Food and Drug Administration , FDA , Sapphire , ACCULINK for Revascularization of Carotids in High Risk Patients registry , IDE , Investigational Device Exemption , Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy registry , Registry Study to evaluate the Neuroshield Bare-Wire Cerebral Protection System and X-Act Stent in patients at high risk for Carotid Endarterectomy
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2004
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
459065
Link To Document :
بازگشت