    Eugenia Nikolsky، نويسنده , , Roxana Mehran، نويسنده , , Amir Halkin، نويسنده , , Eve D. Aymong، نويسنده , , Gary S. Mintz، نويسنده , , Zoran Lasic، نويسنده , , Manuela Negoita، نويسنده , , Martin Fahy، نويسنده , , Shoshana Krieger، نويسنده , , Issam Moussa، نويسنده , , Jeffrey W. Moses، نويسنده , , Gregg W. Stone، نويسنده , , Martin B. Leon، نويسنده , , Stuart J. Pocock، نويسنده , , George Dangas*، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    10
  • From page
    1200
  • To page
    1209
  • Abstract
    Objectives This study was designed to assess the safety of arteriotomy closure devices (ACDs) versus mechanical compression by meta-analysis in patients undergoing percutaneous transfemoral coronary procedures. Background Although ACDs are widely applied for hemostasis after percutaneous endovascular procedures, their safety is controversial. Methods Randomized, case-control, and cohort studies comparing access-related complications using ACDs versus mechanical compression were analyzed. The primary end point was the cumulative incidence of vascular complications, including pseudoaneurysm, arteriovenous fistula, retroperitoneal hematoma, femoral artery thrombosis, surgical vascular repair, access site infection, and blood transfusion. Results A total of 30 studies involving 37,066 patients were identified. No difference in complication incidence between Angio-Seal and mechanical compression was revealed in the diagnostic (Dx) setting (odds ratio [OR] 1.08, 95% confidence interval [CI] 0.11 to 10.0) or percutaneous coronary interventions (PCI) (OR 0.86, 95% CI 0.65 to 1.12). Meta-analysis of randomized trials only showed a trend toward less complications using Angio-Seal in a PCI setting (OR 0.46, 95% CI 0.20 to 1.04; p = 0.062). No differences were observed regarding Perclose in either Dx (OR 1.51, 95% CI 0.24 to 9.47) or PCI (OR 1.21, 95% CI 0.94 to 1.54) setting. An increased risk in complication rates using VasoSeal in the PCI setting (OR 2.25, 95% CI 1.07 to 4.71) was found. The overall analysis favored mechanical compression over ACD (OR 1.34, 95% CI 1.01 to 1.79). Conclusions In the setting of Dx angiography, the risk of access-site-related complications was similar for ACD compared with mechanical compression. In the setting of PCI, the rate of complications appeared higher with VasoSeal.
  • Keywords
    odds ratio , diagnostic , PCI , Confidence interval , Randomized controlled trial , OR , RCT , Percutaneous coronary intervention , CI , ACD , arteriotomy closure devices , Dx
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2004
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    459426