Polymer-based paclitaxel-eluting stents reduce in-stent neointimal tissue proliferation: A serial volumetric intravascular ultrasound analysis from the TAXUS-IV trial Original Research Article
Author/Authors :
Neil J. Weissman، نويسنده , , Joerg Koglin، نويسنده , , David A. Cox، نويسنده , , James Hermiller، نويسنده , , Charles O’Shaughnessy، نويسنده , , James Tift Mann، نويسنده , , Mark Turco، نويسنده , , Ronald Caputo، نويسنده , , Patrick Bergin، نويسنده , , Joel Greenberg، نويسنده , , Michael Kutcher، نويسنده , , S. Chiu Wong، نويسنده , , Warren Strickland، نويسنده , , Michael Mooney، نويسنده , , Mary E. Russell، نويسنده , , Stephen G. Ellis، نويسنده , , Gregg W. Stone، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
Objectives
The aim of this study was to use serial volumetric intravascular ultrasound (IVUS) to evaluate the effects of polymer-based, paclitaxel-eluting stents on in-stent neointima formation and late incomplete stent apposition.
Background
The TAXUS-IV trial demonstrated that the slow-release, polymer-based, paclitaxel-eluting stent reduces angiographic restenosis and the need for repeat revascularization procedures. Serial IVUS studies reveal details of the pattern of vascular responses provoked by stent implantation that provide insight into device safety and efficacy.
Methods
In the TAXUS-IV trial, patients were randomized to the slow-release, polymer-based, paclitaxel-eluting TAXUS stent or a bare-metal EXPRESS stent (Boston Scientific Corp., Natick, Massachusetts). As part of a formal substudy, complete volumetric IVUS data were available in 170 patients, including 88 TAXUS patients and 82 controls, at implantation and at nine-month follow-up.
Results
No baseline differences were present in the clinical characteristics or IVUS parameters between the control and TAXUS groups. At nine-month follow-up, IVUS lumen volumes were larger in the TAXUS group (123 ± 43 mm3 vs. 104 ± 44 mm3, p = 0.005), due to a reduction in neointimal volume (18 ± 18 mm3 vs. 41 ± 23 mm3, p < 0.001). Millimeter-by-millimeter analysis within the stent demonstrated uniform suppression of neointimal growth along the entire stent length. Late lumen loss was similar at the proximal edge of the stent between the two groups, and reduced with the TAXUS stent at the distal edge (p = 0.004). Incomplete stent apposition at nine months was observed in only 3.0% of control and 4.0% of TAXUS stents (p = 0.12).
Conclusions
Polymer-based, paclitaxel-eluting TAXUS stents are effective in inhibiting neointimal tissue proliferation, and do not result in late incomplete stent apposition.
Keywords :
IVUS , intravascular ultrasound , external elastic membrane , EEM
Journal title :
JACC (Journal of the American College of Cardiology)