Title of article
Movement of the Esophagus During Left Atrial Catheter Ablation for Atrial Fibrillation Original Research Article
Author/Authors
Eric Good، نويسنده , , Hakan Oral، نويسنده , , Kristina Lemola، نويسنده , , Jihn Han، نويسنده , , Kamala Tamirisa، نويسنده , , Petar Igic، نويسنده , , Darryl Elmouchi، نويسنده , , David Tschopp، نويسنده , , Scott Reich، نويسنده , , Aman Chugh، نويسنده , , Frank Bogun، نويسنده , , Frank Pelosi Jr، نويسنده , , Fred Morady، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
4
From page
2107
To page
2110
Abstract
Objectives
The aim of this study was to describe the extent of esophageal mobility that occurs during catheter ablation for atrial fibrillation under conscious sedation.
Background
Ablation along the posterior left atrium may cause an atrioesophageal fistula. One strategy for avoiding this risk is to not deliver radiofrequency energy at sites in contact with the esophagus.
Methods
In 51 consecutive patients with atrial fibrillation who underwent left atrial ablation under conscious sedation, digital cine-fluoroscopic imaging of the esophagus was performed in two views after ingestion of barium paste at the beginning and end of the ablation procedure. Movement of the esophagus was determined at the superior, mid-, and inferior parts of the posterior left atrium in reference to the spine.
Results
Mean esophageal movement was 2.0 ± 0.8 cm (range = 0.3 to 3.8 cm) at the superior, 1.7 ± 0.8 cm (range = 0.1 to 3.5 cm) at the mid-, and 2.1 ± 1.2 cm (range = 0.1 to 4.5 cm) at the inferior levels. In 67% of the 51 patients, the esophagus shifted by ≥2 cm, and in 4% there was ≥4 cm of lateral movement. The mean change in esophageal luminal width was 5 ± 7 mm (range = 0 to 36 mm) at the superior, 5 ± 7 mm (range = 0 to 32 mm) at the mid-, and 6 ± 7 mm (range = 0 to 21 mm) at the inferior levels of the posterior left atrium.
Conclusions
The esophagus often is mobile and shifts sideways by ≥2 cm in a majority of patients undergoing catheter ablation for atrial fibrillation under conscious sedation. Therefore, real-time imaging of the esophagus may be helpful in reducing the risk of esophageal injury during radiofrequency ablation along the posterior left atrium.
Keywords
esophagus , Atrial fibrillation , Cs , AF , coronary sinus catheter , Eso