• Title of article

    Accuracy of 64-Slice Computed Tomography to Classify and Quantify Plaque Volumes in the Proximal Coronary System: A Comparative Study Using Intravascular Ultrasound Original Research Article

  • Author/Authors

    Alexander W. Leber، نويسنده , , Alexander Becker، نويسنده , , Andreas Knez، نويسنده , , Franz von Ziegler، نويسنده , , Marc Sirol، نويسنده , , Konstantin Nikolaou، نويسنده , , Bernd Ohnesorge، نويسنده , , Zahi A. Fayad، نويسنده , , Christoph R. Becker، نويسنده , , Maximilian Reiser، نويسنده , , Gerhard Steinbeck، نويسنده , , Peter Boekstegers، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    6
  • From page
    672
  • To page
    677
  • Abstract
    Objectives We evaluated the accuracy of a new 64-slice computed tomography (CT) scanner, compared with intravascular ultrasound, to visualize atherosclerosis in the proximal coronary system. Background Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification. Methods In 20 patients, a 64-slice CT scan (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) and an intravascular ultrasound investigation of vessels without stenosis >50% was performed. Diagnostic image quality with 64-slice CT was obtained in 36 vessels in 19 patients. Results In these vessels, which were divided in 3-mm sections, 64-slice CT enabled a correct detection of plaque in 54 of 65 (83%) sections containing noncalcified plaques, 50 of 53 (94%) sections containing mixed plaques, and 41 of 43 (95%) sections containing calcified plaques. In 192 of 204 (94%) sections, atherosclerotic lesions were excluded correctly. In addition, 64-slice CT enabled the visualization of 7 of 10 (70%) sections revealing a lipid pool and could identify a spotty calcification pattern in 27 of 30 (90%) sections. The correlation coefficient to determine plaque volumes per vessel was r2 = 0.69 (p < 0.001) with an underestimation of mixed and noncalcified plaque volumes (p < 0.03) and a trend to overestimate calcified plaque volumes by 64-slice CT. The interobserver variability to determine plaque volumes was 37%. Interobserver agreement to identify atherosclerotic sections was good (Cohen’s kappa coefficient = 0.75). Conclusions We conclude that 64-slice CT reveals encouraging results to noninvasively detect different types of coronary plaques located in the proximal coronary system. The ability to determine plaque burden currently is hampered by mainly an insufficient reproducibility.
  • Keywords
    computed tomography , CT , IVUS , intravascular ultrasound , MDCT , multi-detector computer tomography
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2006
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    460544