Title of article :
Vocal cord paralysis after vagus nerve stimulator battery replacement successfully treated with medialization thyroplasty
Author/Authors :
Matthew Hoerth، نويسنده , , Joseph Drazkowski، نويسنده , , Joseph Sirven، نويسنده , , Michael Hinni، نويسنده , , Benn Smith، نويسنده , , David Labiner، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
3
From page :
788
To page :
790
Abstract :
The vagus nerve stimulator (VNS) has been used effectively for partial seizure disorders, however many patients suffer from side effects of alterations in voice. This case describes a new remediable adverse effect of the VNS. A patient with medically intractable epilepsy had improvement of his seizure control with VNS therapy after titrating him to a high output and rapid cycling paradigm with essentially no side effects. After a battery replacement, he was restarted on his previous settings and subsequently developed a hoarse voice. He was found to have complete left vocal cord paralysis, an adverse effect attributed to a rapid titration to his previous high output and rapid cycling paradigm. This side effect has not been previously described in the literature. The patient subsequently had a medialization thyroplasty with resolution of his hoarse voice.
Keywords :
Epilepsy , Seizure , Vagus nerve stimulator , Hoarse voice , Medialization thyroplasty
Journal title :
Clinical Neurology and Neurosurgery
Serial Year :
2007