Title of article
Characterization of Plaque Prolapse After Drug-Eluting Stent Implantation in Diabetic Patients: A Three-Dimensional Volumetric Intravascular Ultrasound Outcome Study Original Research Article
Author/Authors
Hideki Futamatsu، نويسنده , , Manel Sabaté، نويسنده , , Dominick J. Angiolillo، نويسنده , , Pilar Jiménez-Quevedo، نويسنده , , Cecilia Corros، نويسنده , , Kino Morikawa-Futamatsu، نويسنده , , Fernando Alfonso، نويسنده , , Julie Jiang، نويسنده , , Pavel Cervinka، نويسنده , , Rosana Hernandez-Antolin، نويسنده , , Carlos Macaya، نويسنده , , Theodore A. Bass، نويسنده , , Marco A. Costa، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
7
From page
1139
To page
1145
Abstract
Objectives
The aim of this research was to evaluate the plaque prolapse (PP) phenomenon after bare-metal (BMS) and drug-eluting stent (DES) implantation in patients with diabetes mellitus using 3-dimensional volumetric intravascular ultrasound (IVUS).
Background
Plaque prolapse has been observed in up to 22% of patients treated with BMS. Diabetic patients have a larger atherothrombotic burden and may be more prone to have PP. However, the incidence of PP and its clinical impact after DES implantation is unknown.
Methods
Three-dimensional IVUS was performed after intervention and at 9-month follow-up in 168 patients with diabetes (205 lesions) treated with bare BX Velocity stents ((BX Velocity/Sonic, Cordis, Johnson & Johnson) (BMS, n = 65), sirolimus-eluting stents (Cypher, Cordis) (SES, n = 69), and paclitaxel-eluting stents (Taxus, Boston Scientific, Natick, Massachusetts) (PES, n = 71). Intravascular ultrasound data at the sites of PP were compared with stented segments without PP in each lesion. Outcomes were evaluated at 9- and 12-month follow-up.
Results
There were 42 sites of PP (BMS = 11, SES = 11, PES = 20, p = NS) in 34 stented segments of 205 (16.6%) lesions. Plaque prolapse was more frequent in the right coronary artery and in chronic total occlusion lesions. Post-procedure PP volume was 1.95 mm3 in BMS, 2.96 mm3 in SES, and 4.53 mm3 in PES. At follow-up, tissue volume increased at PP sites in both BMS and PES, but not after SES. Neointimal proliferation was similar between PP and non-PP sites. Stent thrombosis and restenosis rates were similar between PP and non-PP lesions.
Conclusions
The incidence of PP after implantation of new generation tubular stents in patients with diabetes remains high. Drug-eluting stent implantation was not associated with increased risk of PP. Plaque prolapse was not associated with stent thrombosis or increased neointimal proliferation.
Keywords
BMS , 3D , Diabetes , DES , EEM , PP , IVUS , CSA , DS , intravascular ultrasound , Cross-sectional area , MLD , external elastic membrane , minimal lumen diameter , diameter stenosis , drug-eluting stents , bare-metal stents , Diabetes and Sirolimus-Eluting Stent trial , 3-dimensional , plaque prolapse
Journal title
JACC (Journal of the American College of Cardiology)
Serial Year
2006
Journal title
JACC (Journal of the American College of Cardiology)
Record number
472020
Link To Document