Title of article :
A Novel Two-Dimensional Echocardiographic Image Analysis System Using Artificial Intelligence-Learned Pattern Recognition for Rapid Automated Ejection Fraction Original Research Article
Author/Authors :
Maxime Cannesson، نويسنده , , Masaki Tanabe، نويسنده , , Matthew S. Suffoletto، نويسنده , , Dennis M. McNamara، نويسنده , , Shobhit Madan، نويسنده , , Joan M. Lacomis، نويسنده , , John Gorcsan III، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
10
From page :
217
To page :
226
Abstract :
Objectives We sought to test the hypothesis that a novel 2-dimensional echocardiographic image analysis system using artificial intelligence-learned pattern recognition can rapidly and reproducibly calculate ejection fraction (EF). Background Echocardiographic EF by manual tracing is time consuming, and visual assessment is inherently subjective. Methods We studied 218 patients (72 female), including 165 with abnormal left ventricular (LV) function. Auto EF incorporated a database trained on >10,000 human EF tracings to automatically locate and track the LV endocardium from routine grayscale digital cineloops and calculate EF in 15 s. Auto EF results were independently compared with manually traced biplane Simpson’s rule, visual EF, and magnetic resonance imaging (MRI) in a subset. Results Auto EF was possible in 200 (92%) of consecutive patients, of which 77% were completely automated and 23% required manual editing. Auto EF correlated well with manual EF (r = 0.98; 6% limits of agreement) and required less time per patient (48 ± 26 s vs. 102 ± 21 s; p < 0.01). Auto EF correlated well with visual EF by expert readers (r = 0.96; p < 0.001), but interobserver variability was greater (3.4 ± 2.9% vs. 9.8 ± 5.7%, respectively; p < 0.001). Visual EF was less accurate by novice readers (r = 0.82; 19% limits of agreement) and improved with trainee-operated Auto EF (r = 0.96; 7% limits of agreement). Auto EF also correlated with MRI EF (n = 21) (r = 0.95; 12% limits of agreement), but underestimated absolute volumes (r = 0.95; bias of −36 ± 27 ml overall). Conclusions Auto EF can automatically calculate EF similarly to results by manual biplane Simpson’s rule and MRI, with less variability than visual EF, and has clinical potential.
Keywords :
2D , magnetic resonance imaging , MRI , ejection fraction , LV , left ventricle/ventricular , EF , 2-dimensional
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2007
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
472278
Link To Document :
بازگشت