Title of article :
Alternate Circulating Pro-B-Type Natriuretic Peptide and B-Type Natriuretic Peptide Forms in the General Population Original Research Article
Author/Authors :
Carolyn S.P. Lam، نويسنده , , John C. Burnett Jr، نويسنده , , Lisa Costello-Boerrigter، نويسنده , , Richard J. Rodeheffer، نويسنده , , Margaret M. Redfield، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
Objectives
This study was designed to determine whether alternate pro-B-type natriuretic peptide (proBNP) and BNP forms circulate in the general population.
Background
Bioactive BNP1-32 and NT-proBNP1-76 are derived from a precursor molecule, proBNP1-108. Recent data suggest that aminodipeptidase-processed forms of BNP1-32 (BNP3-32) and of proBNP1-108 itself (proBNP3-108) may circulate and have additional diagnostic potential.
Methods
Residents (age ≥45 years) of Olmsted County, Minnesota, underwent medical review, echocardiography, and phlebotomy for 2 novel assays specific for proBNP3-108 and BNP3-32 and 2 commercial assays (Triage BNP and Roche NT-proBNP). Groups included normal subjects (n = 613), cardiovascular disease with normal ventricular function (n = 1,043), preclinical ventricular dysfunction (ALVD, n = 130), and chronic heart failure (HF, n = 52).
Results
ProBNP3-108 levels were above assay detection limits in 68% of normal subjects (50th; 25th to 75th percentiles: 7.85; 3.00 to 22.45 pmol/l) and correlated with age, gender, body size, and renal function and with results of commercial assays. ProBNP3-108 levels were higher in ALVD (17.88; 6.07 to 42.76 pmol/l) or HF (42.75; 20.51 to 65.73 pmol/l), where they correlated more strongly with commercial assays. BNP3-32 was above assay detection limits in 22% of normal subjects; levels were not correlated with age, body size, or renal function but were higher in HF. Neither novel assay was superior to commercial assays for the detection of ALVD or HF.
Conclusions
The presence of alternate circulating proBNP and BNP forms provides evidence for diverse proBNP and BNP processing in the general population. The physiologic consequences of these observations, both in terms of assay performance and endogenous BNP bioactivity, deserve further study.
Keywords :
AA , cardiovascular , BSA , Receiver operating characteristic , amino acid , heart failure , glomerular filtration rate , ejection fraction , ROC , Hf , CV , BNP , EF , B-type natriuretic peptide , GFR , NT , body surface area , mDC , ALVD , asymptomatic left ventricular dysfunction , minimal detectable concentration , N-terminal
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)