Title of article
Reliable High-Speed Coronary Computed Tomography in Symptomatic Patients Original Research Article
Author/Authors
Annick C. Weustink، نويسنده , , Willem B. Meijboom، نويسنده , , Nico R. Mollet، نويسنده , , Masato Otsuka، نويسنده , , Fransesca Pugliese، نويسنده , , Carlos van Mieghem، نويسنده , , Roberto Malago، نويسنده , , Niels van Pelt، نويسنده , , Marcel L. Dijkshoorn، نويسنده , , *† Filippo Cademartiri، نويسنده , , * Gabriel P. Krestin، نويسنده , , Pim J. De Feyter، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
9
From page
786
To page
794
Abstract
Objectives
Our objective was to prospectively evaluate the diagnostic performance of the high-speed dual-source computed tomography scanner (DSCT), with an increased temporal resolution (83 ms), for the detection of significant coronary lesions (≥50% lumen diameter reduction) in a clinically wide range of patients.
Background
Cardiac motion artifacts may decrease coronary image quality with use of earlier computed tomography scanners that have a limited temporal resolution.
Methods
We prospectively studied 100 symptomatic patients (79 men, 21 women, mean age 61 ± 11 years) with atypical (18%) or typical (55%) angina pectoris, or unstable coronary artery disease (27%) scheduled for conventional coronary angiography. Mean scan time was 8.58 ± 1.52 s. Mean heart rate was 68 ± 11 beats/min. Quantitative coronary angiography was used as the standard of reference. Irrespective of image quality or vessel size, all segments were included for analysis.
Results
Invasive coronary angiography demonstrated no significant disease in 23%, single-vessel disease in 31%, and multivessel disease in 46% of patients; 1,489 coronary segments, containing 220 significant (14.8%) stenoses, were available for analysis. Sensitivity, specificity, and positive and negative predictive values of DSCT coronary angiography for the detection of significant lesions on a segment-by-segment analysis were 95% (95% confidence interval [CI] 90 to 97), 95% (95% CI 93 to 96), 75% (95% CI 69 to 80), 99% (95% CI 98 to 99), respectively, and on a patient-based analysis 99% (95% CI 92 to 100), 87% (95% CI 65 to 97), 96% (95% CI 89 to 99), and 95% (95% CI 74 to 100), respectively.
Conclusions
Noninvasive DSCT coronary angiography is highly sensitive to detect and to reliably rule out the presence of a significant coronary stenosis in patients presenting with atypical or typical angina pectoris, or unstable coronary artery disease.
Keywords
computed tomography , CT , CCA , Confidence interval , CI , QCA , quantitative coronary angiography , conventional coronary angiography , DSCT , dual-source computed tomography scanner
Journal title
JACC (Journal of the American College of Cardiology)
Serial Year
2007
Journal title
JACC (Journal of the American College of Cardiology)
Record number
472734