• Title of article

    Is It Reasonable to Treat All Calcified Stenotic Aortic Valves With a Valved Stent?: Results From a Human Anatomic Study in Adults Original Research Article

  • Author/Authors

    Rachid Zegdi، نويسنده , , Vlad Ciobotaru، نويسنده , , Miléna Noghin، نويسنده , , Ghassan Sleilaty، نويسنده , , Antoine Lafont، نويسنده , , Christian Latrémouille، نويسنده , , Alain Deloche، نويسنده , , Jean-Noël Fabiani، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    6
  • From page
    579
  • To page
    584
  • Abstract
    Objectives This study was designed to study the behavior of a stent deployed inside human stenotic aortic valves. Background Endovascular valved stent (VS) implantation is a promising new therapy for patients with severe calcific aortic stenosis (AS). The precise characteristics of stent deployment in humans have been poorly studied so far. Methods Thirty-five patients with severe AS were included in the study. Sixteen patients (46%) had bicuspid aortic valves. A self-expandable stent specifically designed for VS implantation was deployed intraoperatively inside the aortic valve before surgical aortic valve replacement. Results In tricuspid aortic valves, the shape of stent deployment was circular, triangular, or elliptic in 68%, 21%, or 11%, respectively. Noncircular stent deployment was frequent in bicuspid aortic valves (the elliptic deployment being the rule [79%]), and stent underdeployment was constant. The incidence of gaps between the stent external surface and the aortic valve did not differ between tricuspid and bicuspid valves (58% vs. 43%; p = 0.49). Sharp calcific excrescences protruding inside the stent lumen were present in 3 cases (9%). Ex vivo study of a homemade VS confirmed that the regularity of the coaptation line of the leaflets was critically dependent on the presence or the absence of stent misdeployment. Conclusions Stent misdeployment was constant in bicuspid valves and occurred in one-third of cases of tricuspid valves. Premature failure of implanted VS (secondary to valve distortion or traumatic injury to the leaflets by calcific excrescences) might be an important concern in the future.
  • Keywords
    AS , aortic stenosis , Avr , VS , aortic valve replacement , AVI , valved stent , aortic valve implantation
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2008
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    473092