Title of article :
Effect of Dynamic Flow Rate and Orifice Area on Mitral Regurgitant Stroke Volume Quantification Using the Proximal Isovelocity Surface Area Method
Author/Authors :
Thomas Buck، نويسنده , , Bj?rn Plicht، نويسنده , , Philipp Kahlert، نويسنده , , Ingmar M. Schenk، نويسنده , , Peter Hunold، نويسنده , , Raimund Erbel*، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
Objectives
This study sought to determine the effect of dynamic variations of mitral regurgitant flow rate (MRFR) and effective regurgitant orifice area (EROA) on mitral regurgitant stroke volume (MRSV) quantification using 4 different single-point and time-integral proximal isovelocity surface area (PISA) methods using magnetic resonance imaging (MRI) for reference.
Background
Using PISA provides measures of MRFR, but calculating MRSV is challenging because of dynamic variations in the flow profile dependent on the underlying mechanism of mitral regurgitation (MR). Although various single-point and time-integral approaches have been described to overcome this limitation, uncertainty exists about the accuracy and feasibility of these methods in routine clinical practice.
Methods
In 73 patients with MR of different etiologies, MRSV was calculated from an apical 4-chamber view using the following 4 hemispheric PISA methods: 1) PISA-velocity–time integral (VTI) = midsystolic MRFR by PISA × regurgitant flow VTI/peak velocity; 2) simplified PISA = midsystolic MRFR/3.25; 3) serial PISA = sum of instantaneous MRFRs over serial 2-dimensional frames; and 4) M-mode PISA = time-integral of MRFRs from color M-mode. The MRSV by MRI was calculated from mitral inflow minus aortic outflow.
Results
Single-point PISA methods yielded greater underestimation of MRSV (mean error: −13.3 ± 10.2 ml [PISA-VTI]; −13.5 ± 10.3 ml [simplified PISA]), particularly in functional MR, compared with time-integral PISA methods accounting for variations of MRFR and EROA over time (mean error: −8.0 ± 6.4 ml [M-mode PISA]; −8.7 ± 7.4 ml [serial PISA]).
Conclusions
Depending on the underlying mechanism of MR, dynamic variations of MRFR and EROA revealed important limitations of MRSV calculation using single-point and time-integral PISA methods.
Keywords :
Echocardiography , mitral regurgitation , proximal isovelocity surface area , effective regurgitant orifice area , dynamic variation
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)