Title of article :
Electrocardiographic identification of increased left ventricular mass by simple voltage-duration products
Author/Authors :
Peter M. Okin، نويسنده , , Mary J. Roman، نويسنده , , Richard B. Devereux، نويسنده , , Paul Kligfield، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
7
From page :
417
To page :
423
Abstract :
Objectives. This study was conducted to validate the hypothesis that the product of QRS voltage and duration, as an approximation of the time-voltage are of the QRS complex, can improve the electrocardiographic (ECG) detection of echocardiographically determined left ventricular hypertrophy and to further assess the relative contribution of QRS duration to the ECG detection of hypertrophy. Background. The ECG identification of left ventricular hypertrophy has been limited by the poor sensitivity of standard voltage criteri alone. However, increases in left ventricular mass can be more accurately related to increases in the time-voltage are of the QRS complex than to changes in QRS voltage or duration alone. Methods. Standard 12-lead ECGs and echocardiograms were obtained for 389 patients, including 116 patients with left ventricular hypertrophy. Simple voltage-duration products were calculated by multiplying Cornell voltage by QRS duration (Cornell product) and the 12-lead sum of voltage by QRS duration (12-lead product). Results. In stepwise logistic regression model that also induced Cornell voltage, Sokolow-Lyon voltage, age and gender, QRS duration remained highly significant predictor of the presence of left ventricular hypertrophy (chi-square 26.9, p < 0.0001). At matched specificity of 96%, each voltage-duration product significantly improved sensitivity for the detection of left ventricular hypertrophy compared with simple voltage criteri alone (Cornell product 37% vs. Cornell voltage 28%, p < 0.02, and 12-lead product 50% vs. 12-lead voltage 43%, p < 0.005). Sensitivities of both the Cornell product and the 12-lead product were significantly greater than the 27% sensitivity of QRS duration alone (p < 0.01 vs. p < 0.001), the 20% sensitivity of Romhilt-Estes point score >4 (p < 0.001) and the 33% sensitivity of the best-fit logistic regression model in this cohort (p < 0.05 vs. p < 0.001). Conclusions. QRS duration is an independent ECG predictor of the presence of left ventricular hypertrophy, and the simple product of either Cornell voltage or 12-lead voltage and QRS duration significantly improves identification of left ventricular hypertrophy relative to other ECG criteri that use QRS duration and voltages in linear combinations.
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
1995
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
478398
Link To Document :
بازگشت