• Title of article

    Intravascular ultrasound after low and high inflation pressure coronary artery stent implantation

  • Author/Authors

    Günter G?rge، نويسنده , , Michael Haude، نويسنده , , Ge Junbo، نويسنده , , Elisabeth Voegele، نويسنده , , Thomas Gerber، نويسنده , , Hans-Jürgen Rupprecht، نويسنده , , Jürgen Meyer، نويسنده , , Raimund Erbel*، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1995
  • Pages
    6
  • From page
    725
  • To page
    730
  • Abstract
    Objectives We sought to characterize the differences seen after low or high pressure coronary artery stent deployment as assessed by intravascular ultrasound. Background Until 1992, the success of stent deployment was assessed by angiographic criteri only, but in 1993 the procedure was expanded to include postprocedural single-use intravascular ultrasound imaging. Ultrasound criteri for successful stent deployment were 1) symmetry, 2) minimal lumen diameter >3.0 mm, 3) no echo-free spaces between the stent and the vessel, and 4) no uncovered dissections. Methods We used mechanical 4.8F or 3.5F 20- or 30-MHz monorail single-use intravascular ultrasound catheters. Results Fifty-two patients were included, 28 treated in 1991 and 1992 (group A) and 24 treated in 1993 or 1994 (group B); 87% of patients underwent elective stent implantation. The number of echocardiographic studies per patient increased from 1 ± 0.1 (mean ± SD) in group to 2.0 ± 0.85 in group B. Mean maximal balloon size increased from 3.3 ± 0.33 to 3.73 ± 0.24 mm and maximal inflation pressure from 6.9 ± 1.1 to 15.8 ± 2.4 bar (p < 0.001). The eccentricity index was 0.915 ± 0.04 in group B versus 0.87 ± 0.05 in group A. Minimal lumen diameter measured by echocardiography increased from 2.55 ± 0.41 mm in group to 3.14 ± 0.37 mm in group B. The final mean values per crosssectional are as percent of calculated balloon are were similar in group (67.5 ± 23%) and group B (66.5 ± 22.9%). No major acute complications occurred in either group; subacute thrombosis developed in two patients, both in group A. Conclusions Intravascular ultrasound dat confirm that high pressure stent deployment leads to increased minimal lumen area. Despite high pressure stent deployment, homogeneous stent geometry and optimal stent expansion were not observed in all patients.
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    1995
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    478713