• Title of article

    Conscious Sedation With Combined Hypnotic Agents for Implantation of Implantable Cardioverter-Defibrillators

  • Author/Authors

    Antonio Pacifico MD FACC، نويسنده , , Félix R Cedillo-Salazar MD، نويسنده , , Nadim Nasir Jr. MD، نويسنده , , FACC، نويسنده , , Timothy K Doyle MD FACC، نويسنده , , Philip D Henry MD FACC، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    5
  • From page
    769
  • To page
    773
  • Abstract
    Objectives. The objective of this study was to evaluate the feasibility, safety and efficacy of placing implantable cardioverter-defibrillators (ICDs) in the electrophysiology laboratory using conscious sedation with combined hypnotic agents and deep sedation with etomidate. Background. Implantable cardioverter-defibrillators with transvenous leads permit the use of simplified implantation techniques similar to those used for the insertion of permanent pacemakers. However, implantation of ICDs without general anesthesi has thus far gained limited acceptance. Methods. In 162 patients, conscious sedation during ICD placement was achieved with combined intravenous midazolam, morphine and promethazine (Phenergan). Intravenous etomidate was administered to induce deep sedation for defibrillation threshold testing. First-time implantations were in the prepectoral position (n = 142), but some patients with preexisting devices received abdominal implants (n = 20). The results were compared with those of concurrent patients (n = 56) who received prepectoral implants under propofol anesthesi administered by an attending anesthesiologist. Results. The anesthetic protocol was implemented without major intraoperative complications. During deep sedation with etomidate, episodes of apnea, hypoxi or arterial hypotension requiring therapeutic intervention did not occur. During mean (±SD) follow-up period of 257 ± 140 days (median 227, range 14 to 482), there were, among the 162 patients, total of two nonsudden cardiac deaths—one 71 days and the other 157 days after the operation. There were two nonsudden deaths in the concurrent control subjects (n = 56)—one 13 days and the other 110 days after the operation. Conclusions. Implantation of ICDs under conscious sedation with combined hypnotic agents and deep sedation with etomidate is safe and effective procedure with low perioperative morbidity and low long-term complication rates
  • Keywords
    DFT , ICD , IV , implantable cardioverter-defibrillator , intravenously , defibrillation threshold
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    1997
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    480162