Title of article :
Effects of Amiodarone and Its Active Metabolite Desethylamiodarone on the Ventricular Defibrillation Threshold
Author/Authors :
Li Zhou، نويسنده , , Bonnie P. Chen، نويسنده , , Jeffrey Kluger، نويسنده , , Chengde Fan، نويسنده , , Moses S. S. Chow، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
7
From page :
1672
To page :
1678
Abstract :
Objectives. We evaluated whether the reported difference in the ventricular defibrillation threshold (DFT) between short-term intravenous and oral amiodarone is due to the effect of amiodarone’s active metabolite desethylamiodarone (DEA). Background. Amiodarone is frequently used in patients with implantable cardioverter-defibrillator devices (ICD). Long-term oral amiodarone raises the DFT, but intravenous amiodarone has not been shown to have this effect. DEA, an active metabolite of amiodarone, has different electrophysiologic properties than its parent compound and may be responsible for the observed different effects of intravenous and oral amiodarone on DFT. Methods. We ascertained the DFT in 24 pigs randomized to receive intravenous amiodarone, DE or vehicle. Defibrillation was delivered through transvenous lead system using biphasic waveform. The DFT was determined using an up-down DFT algorithm and defined as the average minimal energies resulting in successful defibrillation delivered from ascending and descending serial shocks. Results. Amiodarone caused dose-response increase in DFT (mean ± SD) from 22.7 ± 4.1 (baseline) to 26.1 ± 2.9 (10 mg/kg body weight), p = 0.11, to 34.9 ± 8.2 J (after an additional 15 mg/kg), p = 0.035. DE (10 mg/kg) caused an increase in DFT from 20.5 ± 6.3 to 33.9 ± 13.6 J, p < 0.01. Addition of 15 mg/kg of DE resulted in hemodynamic instability and thus DFT was not obtained. In the control group, DFT decreased from 26.8 ± 7.7 at baseline to 23.1 ± 7.4 (dose 1), p = 0.19, to 22.8 ± 6.2 J (dose 2), p = 0.18. Conclusions. DE increases DFT by greater amount than its parent drug amiodarone. There is an effect of intravenous amiodarone on DFT that is dose dependent.
Keywords :
DEA , DFT , ICD , ECG , Electrocardiogram , Vf , ventricular fibrillation , electrocardiographic , QTc , implantable cardioverter-defibrillator , corrected QT interval , defibrillation threshold , cycle length ventricular fibrillation , VERP , desethylamiodarone , ventricular effective refractory period , VFCL
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
1998
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
480720
Link To Document :
بازگشت